List of Enabled Devices
This page is still being edited and reviewed.
List of devices transferring data to Chemotion ELN​
The following list summarizes those devices for which a transfer routine from the devices to Chemotion ELN was enabled. For most of the devices, a detailed description of the routine is given in the link (last column of the table). If the description is missing, the Chemotion team will provide it soon. Users with questions are welcome to contact the Chemotion team directly. The team constantly works on the integration of new devices, so users who need support for a particular device are encouraged to reach out.
There are several approaches for the automatic transfer:
- transferring data through email provider
- exe running as a program
- powershell script running as a background service
- macro
On the other hand, manual transfer means that the device is not connected to any network and therefore, one manual transfer step is needed. This is usually solved via a direct regular upload of data collections to the Chemotion ELN data exchange server.
| Device Type | Vendor | Model | Software | File type | Data Transfer process |
|---|---|---|---|---|---|
| GC/MS | Agilent | 6890 GC / 5973N MSD | MSD ChemStation E.02 | .D folder | ChemStation Macro (details) |
| GC/MS | Shimadzu | GC-2030 / MS-QP2020 | LabSolutions 4.53SP1 | .gcd->.cdf (MS AIA +others) | exe (details) |
| GC | Shimadzu | Nexis GC-2030 | LabSolutions 5.110 | .gcd -> .cdf (AIA +others) | exe (details) |
| HPLC | Agilent | 1100 | LC ChemStation B.04 | .D folder | ChemStation Macro (details) |
| LC/MS | Agilent | 1100 HPLC / 1100 MSD | MSD ChemStation B.04 | .D folder | ChemStation Macro (details) |
| LC/MS | Agilent | 1260 HPLC / IQ MS | OpenLab CDS 2.6 | .srlt-> .cdf (AIA +others) | exe (details) |
| SEC | Agilent / PSS | 1200 HPLC | PSS winGPC | exe (details) | |
| LC/MS | Shimadzu | LC-40 / LCMS-2020 | OpenLab CDS 2.6 | .lcd -> .cdf (AIA +others) | exe (details) |
| MS | Advion | expression-L CMS | Mass Express | .datx -> .cdf | exe (details) |
| MS | ThermoFisher | MAT95 | xCalibur | .raw | manual |
| NMR | Bruker | Avance 400 | TopSpin or IconNMR | _.zip -> _.dx | email (details) |
| NMR Benchtop | Magritek | 60 Proton Ultra | Spinsolve | automatic backup function (details) | |
| FTIR | Bruker | Alpha II | Opus 8.6 | .dpt | exe (details) |
| FTIR | Bruker | Alpha II | Opus 8.5 | .0 -> .dx | exe (details) |
| Raman | Bruker | MultiRAM | Opus 6.5 | .0 -> .dx | exe (details) |
| UV-VIS | Horiba | Duetta | EzSpec | exe | |
| DSC | Netzsch | DSC 214 | NETZSCH Messung | exe (details) | |
| DSC | TA Instruments | DSC2500 | TRIOS | .tri -> .csv, .xls, .xml | exe (details) |
| TGA | TA Instruments | TGA5500 | TRIOS | .tri -> .csv, .xls, .xml | exe (details) |
| EIS | BioLogic | VMP-300 | EC Lab | EC-Lab raw data binary file(.mpr) | exe (details) |
| Potentiostat | Gamry | 1010 | Framework | exe | |
| Microscope | Leica | STELLARIS 5 | Application Suite X | .jpeg | exe (details) |
List of the devices being worked on or potentially in the pipeline​
| Device Name | Vendor | Model | Software | Data transfer process |
|---|---|---|---|---|
| IR Vertex 80 | Opus | exe | ||
| HPLC | Thermo Fisher | Ultimate 3000 | Chromeleon | exe |
| TGA | exe |